Model Minibody-10201-N (PN 40)
Item number: 110201N12010
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N G 1" (BSP)
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
|
Item number: 110201N12012
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N G 1/2" (BSP)
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
|
Item number: 110201N12012NPT
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N 1/2" NPT
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
|
Item number: 110201N12014
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N G 1/4" (BSP)
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
|
Item number: 110201N12034
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N G 3/4" (BSP)
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
|
Item number: 110201N12038
RIFOka Thermo – Controlled Capsule Trap PN 40
Model Minibody-10201-N G 3/8" (BSP)
Nom. press. stage: |
PN 40 |
Medium: |
Steam condensate |
Function: |
A special liquid contained within the capsule evaporates or condenses due to changes in temperature. The operating temperature is only a few degrees below the boiling point of water. When the temperature rises, the liquid evaporates and the valve closes. |
Characteristics: |
Due to the very slight temperature drop, accumulation of the condensate is reduced. The capsule reacts to temperature changes immediately. This system ensures prevention of losses in live and control steam and is insensitive to water hammer. |
Installation: |
Horizontal or vertical |
|
Click here to download the data-sheet